Heat pump Mitsubishi Electric Zubadan Hydrobox Reversible ERSF-VM2E+PUZ-SHWM80YAA 8 kW
Package contents
| Component | Model and details | Quantity |
|---|---|---|
| Internal unit | ERSF-VM2EModel indicated in the commercial configuration. | 1 |
| Outdoor unit | PUZ-SHWM80YAAModel indicated in the commercial configuration. | 1 |
Not included
- The assembly is not included in the equipment configuration presented.
Optional extras
- Interface Wi-Fi, in the unit compatible version.
Package conditions
- The size shall be determined by the thermal need of the building, the lap temperature and the external design conditions.
- Installation materials, electrical protection, putting into service and hydraulic accessories shall be set out in the project offer.
Description
Air-to-water configuration Mitsubishi Electric for heating and cooling. The commercial heat class shall be 8 kW. The units models and components identified are shown below.
The hydraulic module shall be mounted on the wall. For domestic hot water, the compatible tank and accessories shall be provided in the design configuration; they shall not be presumed to be included in this package.
Performance depends on air and water temperature. Compare values COP / SCOP only for the same test conditions. Check in PDF the supply of each unit and spare heater as well as the spaces required for installation.
Technical specifications
Identification
- Brand
- Mitsubishi Electric
- Models in configuration
- ERSF-VM2E + PUZ-SHWM80YAA
- Configuration
- Wall-mounted hydrobox
Performance
- Thermal power class
- 8 kW Class used in the catalogue. The nominal values and test conditions shall be consulted separately in the documentation; they are not electric consumption.
Date tehnice
- Power supply
- trifazata
- Refrigerant
- R32
- External unit dimensions, electrical backup 2 kW
- 1040 x 1050 x 480
- External Unit Weight
- 106 kg
- Clasa energetica
- A+++
- Operating range
- -30 degrees Celsius
- Maximum temperature of the heat agent
- 70 ° C
Caracteristici
- Agent frigorific
- R32
- Culoare
- White
- Minimum declared external temperature
- -30 grade Celsius
- Tip unitate
- Heat pump
- Wi-Fi
- Optional
PDF documents
Manufacturer documents cover the listed configuration or product series. Check the exact model and document revision before design or installation.
Frequently asked questions
Does it work on heating in winter?
Yes, the configuration is intended for heating. The declared outer limit is -30 degrees Celsius. The available power depends on the air temperature and the lap temperature; for size, the curves in the PDF are consulted.
Where does this kind of unit fit in?
The hydraulic module shall be mounted on the inside, on the wall, and the outer unit in the outer space. The service distances, drainage and documentation requirements shall be respected.
What kind of refrigerant does he use?
The declared refrigerant is R32. The load quantity and installation conditions shall be checked for the exact unit code in PDF.
What's his energy class?
The class indicated in the configuration specifications is A + + +. Class and efficiency shall be read for the energy label regime and conditions.
Can you control it from your phone?
Network control may require a compatible accessory. Interface Wi-Fi, in the unit compatible version. Optional accessories are not implicitly included in the price.
What color is it available?
The version presented is white. The control shall be identified by the exact codes ERSF-VM2E + PUZ-SHWM80YAA.
What's the capacity for the equipment?
The thermal class in the catalogue is 8 kW. The nominal values at each test point are given in specifications and PDF.
What equipment are included?
The presented configuration includes: 1 × ERSF-VM2E; 1 × PUZ-SHWM80YAA. Accessories appearing in the photograph shall only be included if they are listed in the component list.
Power in kW is electric consumption?
No. 8 kW is the heat class used in the catalogue. Electric consumption depends on operating conditions and efficiency. The power values and COP in the datasheet shall be compared to the same air and water temperatures.
What power supply does it require?
The configuration is presented as three-phase. Check in the manual the supply of the external unit, the inner unit and the spare heater; they may have separate requirements.
Does the boiler have hot water included?
A separate boiler is not mentioned in the list of components of this offer. For domestic hot water, the compatible tank and accessories shall be established in the design configuration.
Is the assembly included?
The offer submitted is for equipment. The assembly, the installation materials and the putting into service shall be set separately, depending on the configuration and conditions at the location.
Which accessories should be ordered separately?
Interface Wi-Fi, in the unit compatible version. Confirm the compatibility of the accessories with the exact models in the offer.
Where do I find the datasheet and the textbooks?
The "PDF Files" section on this page contains the available documentation. The range documents are clearly marked; look for the exact unit code and check the revision of the document before design or assembly.
The displayed price and availability are confirmed?
Prices are provisional, displayed free of VAT and VAT, using the simulation rate indicated on the page. The final price NORDLINE, stock, delivery time and guarantee conditions shall be confirmed for the model and quantity requested.










